PSFD analysis of Multisample Aggregate.
Contributors
Description
PSFD Analysis concucted on the 12 trays AIVA images. We measured the largest axis of 72776 particles, which ranged from 0.03 to 36.64 mm. The power-law value we computed for this PSFD is -2.1 +- 0.3 and the Xmin is 1.1 +- 0.3.
Info
OSIRIS-REx
OREX-800003-0
OREX-800002-0
OREX-800001-0
OREX-800013-0
OREX-800012-0
OREX-800004-0
OREX-800008-0
OREX-800007-0
OREX-800006-0
OREX-800005-0
OREX-800011-0
OREX-800010-0
20250220_PSFD_JSC-ARES_multiSample_1
How To Cite
Pajola, M., Tusberti, F., 2025. PSFD analysis of Multisample Aggregate., Version 1.0. Astromaterials Data Archive. https://doi.org/10.60707/fwkp-de27 Accessed 2026-08-24.
Analytical Method
Files
Select a file for preview.
Funding Sources
This material is supported by NASA under contract NNM10AA11C issued through the New Frontiers program.